產品特點: 高(gao)壓(ya)開關(guan)設備一般包括高(gao)壓(ya)斷路(lu)(lu)器、隔離開關(guan)、負荷(he)開關(guan)、熔斷器及(ji)高(gao)壓(ya)開關(guan)柜(ju)等。 1.高(gao)壓(ya)斷路(lu)(lu)器 在(zai)設備正常運(yun)
高壓(ya)開關(guan)(guan)設備一般包括高壓(ya)斷路(lu)器(qi)、隔離(li)開關(guan)(guan)、負(fu)荷(he)開關(guan)(guan)、熔斷器(qi)及高壓(ya)開關(guan)(guan)柜等(deng)。
1.高壓斷路器
在設(she)備正常運(yun)行時,高壓(ya)斷(duan)路(lu)器主要用(yong)于接通或(huo)切斷(duan)負荷電(dian)流;在設(she)備發生故(gu)障或(huo)嚴重過負荷時,高壓(ya)斷(duan)路(lu)器可用(yong)于自動、迅速地(di)切斷(duan)故(gu)障電(dian)流(借(jie)助繼電(dian)保護裝(zhuang)置),以防止事故(gu)發生。高壓(ya)斷(duan)路(lu)器主要由(you)導電(dian)回路(lu)、滅弧室、外(wai)殼、絕緣支體、操作和傳動機構等部分組成。
2.高壓隔離開關
(1)用途
高壓隔(ge)離(li)(li)開(kai)關的(de)主要用途是(shi):隔(ge)離(li)(li)高壓電(dian)(dian)源,并形(xing)成明顯可見的(de)間(jian)隔(ge),以保(bao)證其他電(dian)(dian)氣沒備能(neng)(neng)夠(gou)安全檢(jian)修(xiu)。但因隔(ge)離(li)(li)開(kai)關沒有滅弧(hu)設(she)置,因而不(bu)能(neng)(neng)接通和切斷負荷電(dian)(dian)流,只能(neng)(neng)接通或(huo)斷開(kai)較小電(dian)(dian)流。
(2)類型
隔離(li)開關按(an)安置位置,可(ke)分為戶(hu)內(nei)型(xing)和(he)戶(hu)外型(xing)(60 kV及(ji)以(yi)上(shang)電壓(ya)無戶(hu)內(nei)型(xing))兩種(zhong):按(an)級數(shu)可(ke)分為單級和(he)三(san)級兩種(zhong);按(an)構造(zao)可(ke)分為雙柱式(shi)、三(san)柱式(shi)和(he)V形三(san)種(zhong);按(an)絕緣情(qing)況可(ke)分為普通型(xing)及(ji)加(jia)強絕緣型(xing)兩類;按(an)接地(di)情(qing)況可(ke)分為帶接地(di)刀閘(zha)和(he)不帶接地(di)刀閘(zha)兩種(zhong)。隔離(li)開關一般為開啟式(shi),特定(ding)條件下也可(ke)定(ding)制成(cheng)封閉式(shi)隔離(li)開關。
3.高壓負(fu)荷開(kai)關
(1)用途
在(zai)高壓配電(dian)裝置(zhi)中,負(fu)(fu)荷開關是專門用(yong)于接通和(he)斷(duan)開負(fu)(fu)荷電(dian)流的(de)電(dian)氣設備(bei);在(zai)裝有(you)脫扣器時,在(zai)過負(fu)(fu)荷的(de)情(qing)況(kuang)下也能自(zi)動跳閘。但其僅(jin)具有(you)簡(jian)單(dan)的(de)滅弧裝置(zhi).因此不能切(qie)斷(duan)短路電(dian)流。在(zai)大多(duo)數情(qing)況(kuang)下,負(fu)(fu)荷開關與高壓熔斷(duan)器(一般為RN型(xing))串聯,借助熔斷(duan)器切(qie)除短路電(dian)流。
(2)類型
高(gao)壓負荷開關有戶(hu)內型(xing)及(ji)戶(hu)外型(xing)兩種,配用(yong)手動(dong)操作(zuo)(zuo)機構(gou)工作(zuo)(zuo)。它具有明顯的斷(duan)路間(jian)隙,也可(ke)起到(dao)普通高(gao)壓隔離開關的作(zuo)(zuo)用(yong)。
4.高壓熔斷器
(1)用途
高壓(ya)熔(rong)斷(duan)器(qi)是常(chang)用(yong)的(de)一種保(bao)(bao)護(hu)電(dian)(dian)(dian)器(qi)。其結構簡(jian)單(dan),廣(guang)泛用(yong)于配電(dian)(dian)(dian)裝置中(zhong),常(chang)用(yong)作保(bao)(bao)護(hu)線路、變(bian)壓(ya)器(qi)及電(dian)(dian)(dian)壓(ya)互感器(qi)等設(she)備。高壓(ya)熔(rong)斷(duan)器(qi)由(you)熔(rong)體(ti)、支持金屬體(ti)的(de)觸頭(tou)和保(bao)(bao)護(hu)外殼三個(ge)部分組成,串接在(zai)電(dian)(dian)(dian)路中(zhong)。若電(dian)(dian)(dian)路發生超負荷(he)或短路故障,當(dang)故障電(dian)(dian)(dian)流超過熔(rong)體(ti)的(de)額定電(dian)(dian)(dian)流時,熔(rong)體(ti)會被迅速加(jia)熱熔(rong)斷(duan),從而切斷(duan)電(dian)(dian)(dian)流防止故障擴大。
(2)類型
高(gao)壓熔斷(duan)器按使用場所可分為(wei)戶(hu)內型和(he)戶(hu)外(wai)型兩種。戶(hu)內型一般(ban)制(zhi)(zhi)成(cheng)規定式,而戶(hu)外(wai)型則全部(bu)制(zhi)(zhi)成(cheng)跌(die)落式(熔絲熔斷(duan)后,熔體(ti)管(guan)自動斷(duan)開)。
5.高壓開關柜
(1)用途
6~35 kV高(gao)(gao)壓(ya)開(kai)關柜(ju)一(yi)般適用(yong)(yong)于(yu)交流50 Hz、3~35 kV電(dian)(dian)壓(ya)的(de)(de)電(dian)(dian)力系統(tong)中(zhong),作為電(dian)(dian)能接受、分配(pei)的(de)(de)通、斷和(he)(he)監(jian)視保(bao)護(hu)(hu)之用(yong)(yong)。它是由制造廠按照一(yi)定的(de)(de)接線方(fang)式,將同一(yi)回路的(de)(de)開(kai)關電(dian)(dian)器(qi)、母(mu)線、測量儀表(biao)、保(bao)護(hu)(hu)電(dian)(dian)器(qi)和(he)(he)輔助(zhu)設備(bei)等都裝配(pei)在封閉(bi)的(de)(de)金(jin)屬柜(ju)中(zhong),成(cheng)套供應用(yong)(yong)戶。這種設備(bei)具有結構緊湊、使(shi)用(yong)(yong)方(fang)便(bian)等特(te)點,因此(ci)廣泛用(yong)(yong)于(yu)控(kong)制和(he)(he)保(bao)護(hu)(hu)變壓(ya)器(qi)、高(gao)(gao)壓(ya)線路和(he)(he)高(gao)(gao)壓(ya)電(dian)(dian)動機等設備(bei)中(zhong)。
(2)類型
高壓(ya)開關柜(ju)主要包括固定式和手車式兩(liang)種(zhong)(zhong)。按結構的不(bu)同,可分(fen)(fen)為(wei)開啟式、封閉式和半(ban)封閉式三(san)種(zhong)(zhong);按使用環境的不(bu)同。可分(fen)(fen)為(wei)戶內和戶外(wai)兩(liang)種(zhong)(zhong);按操作方式的不(bu)同,可分(fen)(fen)為(wei)電磁(ci)操動(dong)(dong)機構、彈簧操動(dong)(dong)機構和手動(dong)(dong)操動(dong)(dong)機構等(deng)。